毛片av在线_尤物av在线_日韩久久久_www.日韩在线_午夜久久_亚洲久久久_91在线精品一区二区

Home | About Biaoqi | News | Product | Contact | 中文

Contact an Biaoqi Applications Scientist

 
Product List
QSpec
OceanOpticsSpectrometer
Light Sources
New Product
* PL-3000 Photoluminescence Spectrometer
* GLIS-3000 GEM Luminous Imaging 
* bluLoop Multi-LED Light Source
* HL-2000 Tungsten Halogen Light 
* LS-1 Tungsten Halogen Light So
* DH-2000 Deuterium Tungsten Halogen&
* Balanced Deuterium Tungsten Halogen
* Miniature Deuterium Tungsten Haloge
* D-2000 Deuterium Light Sources
* High-powered Continuous-wave Xenon 
 
Product

Light Sources>> Wavelength Calibration Sources>>HG-1 Mercury Argon Calibration Source for UV-VIS  

HG-1 Mercury Argon Calibration Source


The compact, low-cost HG-1 Mercury Argon Calibration Source is a spectral wavelength calibration source for UV-VIS-Shortwave NIR spectrophotometric systems. The HG-1 produces first order mercury and argon spectral lines from 253-922 nm and second order argon lines to 1700 nm for use in performing fast, reliable spectrometer wavelength calibrations. Easily identifiable mercury and argon spectral emission lines are printed on the HG-1 housing.

The HG-1 is available for

With the HG-1 and an Ocean Optics spectrometer, users can perform wavelength calibration with a spreadsheet program such as Microsoft Excel or a calculator that performs linear regressions. For technical assistance in performing the latter option, click on Calibrating the Wavelength of Your Spectrometer.

The HG-1 features an SMA 905 Connector to couple to Ocean Optics spectrometers and fiber optic accessories, including optical fibers. The HG-1 operates with a 12 VDC power supply (included with the unit) or 9V battery (not included).

User's Tip: Ocean Optics spectrometers are carefully calibrated as part of the company's standard quality assurance process. However, as is the case with all spectrometers, wavelength will drift slightly due to time and environmental conditions. If wavelength accuracy is an important part of your work, consider including calibration spectra with every experiment.

Specifications

Output:

Low-pressure gas discharge lines of mercury and argon

Spectral range:

253-1700 nm

Dimensions (in mm):

125.7 x 70 x 25.8

Power consumption:

250 mA at 12 VDC

Power requirements:

12 VDC wall transformer (included) or
9 VDC battery (additional)

Internal voltage:

600 volts at 30 kHz

Bulb life:

~ 3,500 hours (at 20 mA)

Amplitude stabilization:

~1 minute

Aperture:

3 mm

Connector:

SMA 905

User's Tip: Ocean Optics recommends using the HG-1 with a 50 µm-diameter or smaller optical fiber or entrance slit. The use of  fibers and slits >50 µm in diameter will result in optical resolution (full width, half maximum) that adversely affects wavelength calibration. Also, keep in mind that if the spectrometer has no slit and your experiment involves using optical fibers of different diameters, wavelength re-calibration will be required. That's because optical resolution will vary according to the diameter of the fiber in use -- i.e., a 50 µm fiber will resolve differently than a 100 µm fiber, and so on. Recalibration is also recommended every time that you unscrew the fiber from the SMA 905 Connector on the spectrometer.

Spectral Output

Mercury emission lines are <600 nm. Argon emission lines are >600 nm, and are shown here on an exaggerated amplitude scale.

Strong Hg Emission Lines by Wavelength (nm)

User's Tip: There are more emission lines published here than printed on the label on the HG-1 housing. The label is intended as a quick, convenient reference and does not list every Ar or Hg emission line that exists.

253.652 404.656
296.728 407.783*
302.150 435.833
313.155 546.074**
334.148 576.960
365.015 579.066

* This spectral line will not be evident with spectrometers configured with 300- or 600-lines/mm gratings.

** With spectrometers that have 1200-, 1800-, 2400- or 3600-lines/mm gratings, spectral lines will be evident at 576.96 nm and 579.07 nm.

Strong Ar Emission Lines by Wavelength (nm)

696.543 800.616*
706.722 811.531
714.704 826.452
727.294 842.465
738.398 852.144
750.387 866.794
763.511 912.297
772.376 922.450
794.818

* This spectral line will be evident only with spectrometers configured with 1800-, 2400-, or 3600-lines/mm gratings.

Cuvette Wavelength Calibration Adapter

The PS-HG1-ADP Wavelength Calibration Adapter is a 1-cm square fixture that fits into a 1-cm pathlength sample chamber and connects to the HG-1 via optical fiber. (Neither wavelength calibration standard or fiber is included). The adapter is designed for performing a wavelength calibration for any spectrometer and 1-cm cuvette holder system, whether it's designed by Ocean Optics or another manufacturer.

 
版權所有 2007 廣州標旗光電科技發展股份有限公司 www.aplusconcretedesign.com
地址:廣州市黃埔區彩頻路7號701-1房
電話:(020)38319602 38319620 傳真:(020)38319595 ICP備案:粵ICP備2024341827號 粵公網安備44011202002999
主站蜘蛛池模板: 大陆三级特黄在线播放 | 鲁丝片一区二区三区毛片 | 国产福利在线观看第二区 | 亚洲国产精品成人综合色在线婷婷 | 久久一级视频 | 日本高清午夜色wwwσ | 日本免费人成黄页在线观看视频 | 蜜桃视频www在线观看免费视频 | 日本激情视频一区二区三区 | 青娱乐国产在线 | 亚洲第一a亚洲 | 国产成人在线影院 | 久草免费在线视频 | 欧美精品一二三区 | 久草视频福利在线 | 人人看人人 | 男女激情视频网站 | 久99久视频| 国产日本免费 | 99精品视频不卡在线观看免费 | 日本特黄特色大片免费播放视频 | 91久久网 | 国产一级做a爰片在线 | a毛片免费全部播放毛 | 老子午夜我不卡理论影院 | 久久波多野结衣 | 清纯漂亮小美女准备啪啪 | 激情六月婷婷 | 国产一级淫片a免费播放口 国产一级又色又爽又黄大片 | 操人视频网站 | www射射一区 | 欧美日韩北条麻妃一区二区 | 精品国产91久久久久久久a | 日本在线中文 | 天天草夜夜 | 国产又黄又刺激又爽视频黄 | 国产精品第六页 | 久久宗合色 | 亚洲精品午夜视频 | 日本黄色免费 | 天天草天天干天天 |